Single-Stage Single-Stage
Thermostat Furnace Air Conditioner
RVS/Heat Stage 2 O/B W2
Heat Stage 1 W/W1 W
Compressor Low Y1
Compressor High Y/Y2 Y Y
Fan G G
24VAC Hot Heating Rh R
24VAC Hot Cooling Rc R *
Dry Contact 1 D1
Dry Contact 2 D2 DEHUM
24VAC Common C COM COM
Humidify HUM
Outdoor Air Temp OAT
Remote Room Sensor RRS
OAT/RRS Com OAT/RRS
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor
*
A07760
Fig. 36 -- Single-- stage Furnace with Air Conditioner and Split Power
* Indicates connection may not be required/available.
NOTE: Rc/Rh jumper is cut on the Equipment Control Module.