ITEMS YOU NEED:
Battery should be 12 volt, negative ground with top posts.
ASPAS1BBA007: Minimum 350 CCA at 0° F (Group 26)
ASPAS1BBA012 & ASPAS1BBA015: Minimum 525
CCA at 0° F (Group 26)
40 Amp (7 kW) or 70 Amp (12 kW and 15 kW) double
pole circuit breaker (Must be compatible with your
main distribution panel.)
Grounding rod with grounding strap
Crushed stone or pea gravel (approximately 10-12
cubic feet)
Black poly-film or other vegetation blocking fabric (5-
1/2' x 5')
• Silicone caulk
Pipe sealant (suitable for gaseous fuel connections)
Fasteners (to mount external connection box and
automatic transfer switch with built-in load center)
TOOLS REQUIRED:
Drill, drill bits, hole saw (type and length will be
determined by the materials you will be drilling and
cutting), open-end wrenches or adjustable wrenches,
socket wrenches or nut drivers, standard and Phillips
screwdrivers, level, sledge hammer, channel-lock pliers,
spade shovel, pencil and safety goggles.
Installation Preparation
Air-cooled models only.