Bryant NON-PROGRAMMABLE THERMOSTAT Manual de Instruções Página 53

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 52
53
Single-Stage Single-Stage
Thermostat Furnace Air Conditioner
RVS/Heat Stage 2 O/B W2
Heat Stage 1 W/W1 W
Compressor Low Y1
Compressor High Y/Y2 Y Y
Fan G G
24VAC Hot Heating Rh R
24VAC Hot Cooling Rc R *
Dry Contact 1 D1
Dry Contact 2 D2
24VAC Common C COM COM
Humidify HUM
Outdoor Air Temp OAT
Remote Room Sensor RRS
OAT/RRS Com OAT/RRS
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor
*
A07170
Fig. 24 -- Single--stage Furnace with Air Conditioner and Split Power
* Indicates connection may not be required/available.
NOTE: Rc/Rh jumper is cut on the Equipment Control Module.