Form No. PDS FF1D.18.2
FAN COIL UNITS
FF1DNA,
FF1DNE
Sizes 018, 024, 030
FEATURES
The FF1DNA and FF1DNE Fan Coil units are designed as
upflow indoor air handlers for split-system heat pumps and air
conditioners. They are available with factory- or field-installed
electric heaters both of which include the disconnect. A field-
installed cooling control with disconnect is also available. A TDR
(Time Delay Relay) is included with either the electric heat or
the cooling control packages. The FF1DNE models are avail-
able with a factory installed TXV.
This fan coil may be installed free standing, wall hung or flush
mounted in the wall. The 22-in. wide cabinet size in all models
allows units to fit between standard stud spacings. No return air
ductwork is required if the application provides for return air in
the front of the cabinet through either a louvered closet door or
an optional accessory decorative grille panel.
The cabinet exterior is made of pre-painted galvanized sheet
metal. The cabinet is fully insulated to meet applications in con-
ditioned space. Additional insulation is required if the unit is
installed in an unconditioned space. Unit is supplied with
replaceable filter.
Multispeed direct-drive PSC blower motors have been selected
to provide the proper air handling for both heating and cooling.
Motors are suspended at 3 points on rubber grommets for qui-
eter operation.
All refrigerant lines, electrical power, and thermostat wiring
enter from the top of the cabinet. Sweat-type refrigerant con-
nections on both liquid and suction lines make for swift, low-cost
installation. All service access to the unit is conveniently located
in the front.
The CHECK-FLO-RATER
®
piston ensures efficient and
dependable refrigerant metering, and eliminates potential ser-
vice requirements of other metering devices. The CHECK-FLO-
RATER
®
is located inside the unit, easily accessible for piston
maintenance or changeout.
In addition, units can be factory ordered with a hard shut-off
thermostatic expansion valve (TXV) metering device for perfor-
mance improvement.
The drain pan is constructed of high-impact, sound-deadening,
corrosion-proof polyester resin. Primary and secondary drain
connections exit from the bottom or either side of the cabinet.
FF1D
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1 - FAN COIL UNITS

Form No. PDS FF1D.18.2 FAN COIL UNITS FF1DNA,FF1DNE Sizes 018, 024, 030 FEATURES The FF1DNA and FF1DNE Fan Coil units are designed asupflow indoor air

Página 2 - • TESTING • INSPECTION

—2— MODEL NUMBER NOMENCLATURE CERTIFICATION APPLIES ONLY WHEN THE COMPLETE

Página 3 - INLET AIR

—3— DIMENSIONS — FF1DNA, FF1DNE A98336 OUTLET AIRINLET AIRSUCTION TUBECOIL1 1⁄8″ DIA. KNOCKOUTSIDE VIEW FRONT VIEWTOP VIEWBOTTOM VIEWPRIMARY DRAINP

Página 4 - SPECIFICATIONS

—4— SPECIFICATIONS See notes on page 5. UNITS WITHOUT ELECTRIC HEATERS OR CONTROLSUNIT SIZE 0180 0240 0300RATINGS & PERFORMANCES Nominal Capacity

Página 5 - SPECIFICATIONS Continued

—5— SPECIFICATIONS Continued * Rated in accordance with U.S. Government DOE test procedures and/or ARI Standard 210/240-94.† Use copper wire only.

Página 6

—6— COOLING CAPACITIES (MBtuh) * Saturated suction leaving evaporator coil. COIL REFRIGERANT TEMPERATURE* (°F) UNITSIZEEVAPORATORAIRCFM andBF35 40 45

Página 7 - OTHER ACCESSORIES

—7— AIR DELIVERY (CFM) AT INDICATED EXTERNALSTATIC PRESSURE AND VOLTAGE NOTE: Data reflects a dry coil, filter, and 11-kw electric heater installed. A

Página 8 - SERVICE TRAINING

—8— SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICEUNIT MUST BE INSTALLED IN ACCORDANCEWITH INSTALLATION INSTRUCTIONSCancels: PDS FF1D.18.1Form PDS F